A camera shows a clear entrance during office hours, then a pale haze covers the image after dark. The recorder may still be working. One possible cause is the camera’s own infrared illumination reflecting from a nearby surface or its dome back into the lens.
The hero is an illustration, not recorded footage or an ITZ installation. Orange light represents illumination conceptually; infrared illumination is normally invisible to the human eye.
Compare the same view before and after night mode
Record the camera model, affected channel, lighting conditions and when the haze begins. Compare recorded footage from before and after the day/night change, not only the live view. If other cameras are clear, note how the affected camera’s position and surroundings differ.
Axis’s image-quality troubleshooting guide explains that reflections can appear in night mode even when daytime colour images look normal. A bright patch, noise and motion blur are different symptoms. Give the installer examples rather than changing several exposure settings at once.
Inspect the dome and nearby reflective surfaces
The Axis IR reflection white paper identifies nearby walls, water, dirt, dust and external light sources as possible contributors. A spider web or a surface outside the visible frame can matter because the illumination can cover a wider area than the camera’s displayed view.
Ask an authorised technician to inspect the protective bubble and mounting position safely. Follow the camera manufacturer’s cleaning instructions and avoid scratching the dome. Do not apply an unapproved chemical or coating. If opening the housing is necessary, preserve its seals and any lens-to-dome light barrier according to the installation procedure.
A new sign, wall covering or nearby lamp may have changed the scene since installation. Record those changes. Repositioning the camera or illumination may be more useful than increasing image brightness, but it must preserve the intended field of view and required coverage.
Test the actual after-hours task
- Define what the camera needs to show at the entrance or corridor. Use a permitted staff walk-through without recording unrelated customers for the test.
- Make one approved adjustment at a time and retain the previous settings or configuration record.
- Review the recording while a person moves through the relevant area. A clean still image does not establish that movement is usable.
- Export and play a sample using the normal incident process. Check the night image as well as access to the file.
Use the CCTV export and playback guide for the handover test and the recording retention guide to check how long useful footage remains available. Reducing illumination can reduce glare but can also leave an area too dark; validate the full scene after any change.
Review your CCTV night coverage
ITZ’s commercial CCTV installation service can review camera position, illumination and night testing. Describe the affected channel and when the image becomes hazy.
Bring the camera model and an approved, redacted day/night comparison. Discuss inspection and acceptance checks for the coverage your business needs. Review Your CCTV Night Coverage